BTU sizing chart by square feet and climate zone

Cooling and heating load for common house sizes, in every DOE climate zone. All figures assume 8 ft ceilings, average insulation, average sun and two occupants, so they are a starting point rather than an answer for a particular building.

Change any of those assumptions in the calculator, which uses the same module that generated every number on this page.

Before you buy anything. This is a square-foot estimate, not an ACCA Manual J load calculation. A Manual J uses your building’s real construction, orientation and air leakage, and on a well-sealed house it usually comes out smaller than this. Use this to sanity-check a quote, not to replace one.

What a Manual J actually measures.

Climate zone 1: hot humid

Miami, Key West, Honolulu. Cooling 30 to 35 BTU per sq ft, heating 15 to 25.

Design loads and central equipment size, climate zone 1
Sq ftCooling BTUHeating BTUAC sizeTons
50015,9389,37518,0001.5
60019,12511,25024,0002.0
80025,50015,00030,0002.5
1,00031,87518,75036,0003.0
1,20038,25022,50042,0003.5
1,50047,81328,12548,0004.0
1,60051,00030,00054,0004.5
1,80057,37533,75060,0005.0
2,00063,75037,50060,0005.0
2,50079,68846,87560,0005.0
3,00095,62556,25060,0005.0
3,500111,56365,62560,0005.0
4,000127,50075,00060,0005.0

Climate zone 2: hot

Houston, Orlando, Phoenix, New Orleans. Cooling 27 to 30 BTU per sq ft, heating 20 to 30.

Design loads and central equipment size, climate zone 2
Sq ftCooling BTUHeating BTUAC sizeTons
50014,06311,87518,0001.5
60016,87514,25018,0001.5
80022,50019,00024,0002.0
1,00028,12523,75030,0002.5
1,20033,75028,50036,0003.0
1,50042,18835,62548,0004.0
1,60045,00038,00048,0004.0
1,80050,62542,75054,0004.5
2,00056,25047,50060,0005.0
2,50070,31359,37560,0005.0
3,00084,37571,25060,0005.0
3,50098,43883,12560,0005.0
4,000112,50095,00060,0005.0

Climate zone 3: warm

Atlanta, Dallas, Los Angeles, Charlotte. Cooling 24 to 27 BTU per sq ft, heating 25 to 35.

Design loads and central equipment size, climate zone 3
Sq ftCooling BTUHeating BTUAC sizeTons
50012,56314,37518,0001.5
60015,07517,25018,0001.5
80020,10023,00024,0002.0
1,00025,12528,75030,0002.5
1,20030,15034,50036,0003.0
1,50037,68843,12542,0003.5
1,60040,20046,00042,0003.5
1,80045,22551,75048,0004.0
2,00050,25057,50054,0004.5
2,50062,81371,87560,0005.0
3,00075,37586,25060,0005.0
3,50087,938100,62560,0005.0
4,000100,500115,00060,0005.0

Climate zone 4: mixed

Washington DC, Seattle, St Louis, Nashville. Cooling 22 to 25 BTU per sq ft, heating 30 to 40.

Design loads and central equipment size, climate zone 4
Sq ftCooling BTUHeating BTUAC sizeTons
50011,56316,87518,0001.5
60013,87520,25018,0001.5
80018,50027,00024,0002.0
1,00023,12533,75024,0002.0
1,20027,75040,50030,0002.5
1,50034,68850,62536,0003.0
1,60037,00054,00042,0003.5
1,80041,62560,75042,0003.5
2,00046,25067,50048,0004.0
2,50057,81384,37560,0005.0
3,00069,375101,25060,0005.0
3,50080,938118,12560,0005.0
4,00092,500135,00060,0005.0

Climate zone 5: cool

Chicago, Denver, Boston, Detroit. Cooling 20 to 23 BTU per sq ft, heating 35 to 45.

Design loads and central equipment size, climate zone 5
Sq ftCooling BTUHeating BTUAC sizeTons
50010,56319,37518,0001.5
60012,67523,25018,0001.5
80016,90031,00018,0001.5
1,00021,12538,75024,0002.0
1,20025,35046,50030,0002.5
1,50031,68858,12536,0003.0
1,60033,80062,00036,0003.0
1,80038,02569,75042,0003.5
2,00042,25077,50048,0004.0
2,50052,81396,87554,0004.5
3,00063,375116,25060,0005.0
3,50073,938135,62560,0005.0
4,00084,500155,00060,0005.0

Climate zone 6: cold

Minneapolis, Burlington, Helena. Cooling 18 to 22 BTU per sq ft, heating 40 to 50.

Design loads and central equipment size, climate zone 6
Sq ftCooling BTUHeating BTUAC sizeTons
5009,75021,87518,0001.5
60011,70026,25018,0001.5
80015,60035,00018,0001.5
1,00019,50043,75024,0002.0
1,20023,40052,50024,0002.0
1,50029,25065,62530,0002.5
1,60031,20070,00036,0003.0
1,80035,10078,75036,0003.0
2,00039,00087,50042,0003.5
2,50048,750109,37554,0004.5
3,00058,500131,25060,0005.0
3,50068,250153,12560,0005.0
4,00078,000175,00060,0005.0

Climate zone 7: very cold

Duluth, Grand Forks, International Falls. Cooling 16 to 20 BTU per sq ft, heating 45 to 55.

Design loads and central equipment size, climate zone 7
Sq ftCooling BTUHeating BTUAC sizeTons
5008,75024,37518,0001.5
60010,50029,25018,0001.5
80014,00039,00018,0001.5
1,00017,50048,75018,0001.5
1,20021,00058,50024,0002.0
1,50026,25073,12530,0002.5
1,60028,00078,00030,0002.5
1,80031,50087,75036,0003.0
2,00035,00097,50036,0003.0
2,50043,750121,87548,0004.0
3,00052,500146,25054,0004.5
3,50061,250170,62560,0005.0
4,00070,000195,00060,0005.0

Climate zone 8: subarctic

Fairbanks, Barrow. Cooling 15 to 18 BTU per sq ft, heating 50 to 60.

Design loads and central equipment size, climate zone 8
Sq ftCooling BTUHeating BTUAC sizeTons
5008,06326,87518,0001.5
6009,67532,25018,0001.5
80012,90043,00018,0001.5
1,00016,12553,75018,0001.5
1,20019,35064,50024,0002.0
1,50024,18880,62530,0002.5
1,60025,80086,00030,0002.5
1,80029,02596,75030,0002.5
2,00032,250107,50036,0003.0
2,50040,313134,37542,0003.5
3,00048,375161,25054,0004.5
3,50056,438188,12560,0005.0
4,00064,500215,00060,0005.0

Reading this chart honestly

Three things it cannot know, all of which move the answer:

  • Your ceiling height. Every row assumes 8 ft. At 10 ft, add 25%.
  • Your envelope. A 1960s house with single glazing sits at the top of its zone's band, a current-code build at the bottom. That spread is up to 14% either side of these numbers.
  • Your actual design temperature. Climate zones are broad. A zone spans a real range of design conditions, and the edges of a zone behave more like their neighbours.

Frequently asked questions

How many BTU do I need per square foot?
For cooling, between 15 and 35 BTU per square foot depending on climate zone, roughly 22 to 25 in a mixed climate. For heating, 15 to 60. A single national number does not exist, which is why charts that give one are misleading.
How many BTU for 1,000 square feet?
About 23,125 BTU of cooling in a mixed zone 4 climate, 31,875 BTU in hot and humid zone 1, and 19,500 BTU in cold zone 6, where the heating load of 43,750 BTU matters more.
How many BTU for 2,000 square feet?
Roughly 46,250 BTU of cooling and 67,500 BTU of heating in climate zone 4, at 8 ft ceilings with average insulation.